| Product Type | Modular Safety Gate Box with PROFINET Interface |
| Model Code | MGB-B-A1W2A2-PN |
| Series | MGB (Modular Gate Box System) |
| Core Functions | Access control, door locking, safety monitoring, network integration |
| Safety Standards | ISO 13849-1, IEC 62061, ISO 14119, IEC 60947-5-1 |
| Safety Level | PL e (ISO 13849-1), SIL 3 (IEC 62061) |
| Locking Mechanism | Electromechanical bolt (fail-safe) |
| Monitoring Channels | 1 dual-channel safety input (e.g., for E-stop) + position sensors |
| Safety Outputs | 2 OSSD outputs (semiconductor, 24V DC, 0.5A) |
| Auxiliary Outputs | 2 relay outputs (2 A, 230V AC) for non-safety functions |
| Communication | PROFINET/ProfiSafe (PN suffix) - Conformance Class A |
| Network Protocols | PROFIsafe V2.0, TCP/IP, RT/IRT |
| Operating Voltage | 24 V DC (±15%) |
| Power Consumption | 1.8 W (idle), 15 W (locking engaged) |
| Locking Force | 1,200 N (adjustable) |
| Release Delay | Configurable (0–60 s) |
| Protection Rating | IP65 (front), IP20 (rear) |
| Housing Material | Anodized aluminum (front), polycarbonate (rear) |
| Operating Temperature | -10°C to +55°C |
| Mounting | Front-flush mounting (door frame) |
| Dimensions (W×H×D) | 155 × 80 × 62 mm |
| Weight | 850 g |
| Connection | M12 connectors (safety I/O) + RJ45 (PROFINET) |
| Diagnostics | Multi-color LED (status/fault), PROFIsafe error codes |
| Configuration | Euchner Safety ES software or Siemens TIA Portal (GSDML file) |
| Safety Logic | Pre-configured functions: guard locking, release control, edge monitoring |
| Cybersecurity | PROFIsafe CRC checks, password protection |
| Certifications | CE, UL, TÜV Nord, cULus, RoHS, IECEx |
| Compatibility | Euchner CES-AP controllers, Siemens S7/PROFINET PLCs |